Page 10-490DIG-LINE (Digital Line)
10
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS (TDM Bus) Maintenance to diagnose any active
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV (TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exists, retry the command at 1-minute
intervals a maximum of 5 times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a valid call during the test. The test
has been aborted. Use display port UUCSSpp/PCSSpp to
determine the station extension or attendant number of the
port. Use status station or status attendant to determine
the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests.
(See Chapter 10, "Maintenance Commands and
Trouble-Clearing Aids", for a full description of all possible
states.) You must wait until the port is idle before retesting.
Attendants are always in use (off-hook) if the handset is
plugged in and the port is not busied out.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
Table 10-132. TEST #13 Voice and Control Channel Local Loop Test — Continued