Maintenance Commands and Trouble-Clearing Aids
Page 8-104display alarms
8
For the following output example, the ENTER key was pressed immediately after
entering the display alarms command.
Feature Interactions
If the alarm origination is disabled via "change system-parameters maintenance,"
the "Ack?" field displays blanks no matter what the true acknowledge state is for
the alarm.
Ack? The columns under the “1” and “2” headings denote if the alarm
has been acknowledged by the first and second OSS telephone
numbers, respectively. A "y" in this field means that the alarm has
been acknowledged. A "n" means that the alarm has not been
acknowledged. A "c" means that the alarm resolved and cleared
and the alarm notification was acknowledged. A blank means that
there will be no attempt to report the alarm.
Date Alarmed Day, hour, and minute of alarm.
Date Resolved Day, hour, and minute of resolution. For active alarms this field will
be zero (0).
display alarms
ALARM REPORT
Port Maintenance On Alt Alarm Svc Ack? Date Date
Name Brd? Name Type State 1 2 Alarmed Resolved
02A TONE-BD y MAJOR y n 05/22/20:34 00/00/00:00
01C07 ANL-BD y MINOR n n 05/22/20:26 00/00/00:00
01C0702 ANL-LINE n 311 WARNING IN 05/22/20:26 00/00/00:00
01C0701 ANL-LINE n 1051 WARNING IN 05/22/20:26 00/00/00:00
01C0703 ANL-LINE n 1053 WARNING IN 05/22/20:26 00/00/00:00
01C1505 CO-TRK n 78/01 WARNING OUT 05/22/20:26 00/00/00:00
01C1505 CO-TRK n 78/01 WARNING OUT 05/22/20:26 00/00/00:00
02A0201 TONE-PT n WARNING 05/22/20:34 00/00/00:00
02A TDM-CLK n WARNING 05/23/13:43 00/00/00:00
PN 02B TDM-BUS n WARNING 05/23/14:53 00/00/00:00
Command successfully completed