Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-349CO-TRK (CO Trunk)
10
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS Maintenance to diagnose any active TDM-BUS
errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a tone receiver for the test.
The system may be oversized force.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT Maintenance documentation.
3. If neither condition exists, retry the command at
one-minute intervals a maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT System resources required to run this test are not available.
The port may be busy with a valid call. Use the display port
UUCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable
for certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at 1 minute
intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Table 10-97. TEST #33 Loop Around and
Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page