DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-455DID-TRK (DID Trunk)
10
1004 ABORT The port was seized by a valid call during the test. The test
has been aborted. Use the display port PCSSpp
command to determine the station extension, attendant
number, or trunk group/member number of the port. Use
the status station, status attendant, or status trunk
command to determine the service state of the port. If the
service state indicates that the port is in use, then the port
is unavailable for certain tests. (Refer to the "Status
Commands" section in Chapter 10, "Maintenance
Commands and Trouble-Clearing Aids", for a full
description of all possible states.) You must wait until the
port is idle before retesting. Attendants are always in use
(off-hook), if the handset is plugged in and the port is not
busied out.
1. Retry the command at one-minute intervals a maximum
of five times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1018 ABORT Test disabled via administration. Verify that the
"Maintenance Tests?" field on the Trunk Group Form is set
to "n." To enable the test, issue the change trunk-group x
command where "x" equals the number of the trunk group
to be tested. Then change the entry in the "Maintenance
Tests?" field on the form to "y."
2000 ABORT Response to the test was not received within the allowable
time period.
1. Retry the command at 1-minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Table 10-125. TEST #33 Loop Around and Conference
Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page