DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1211S-SYN-PT (Speech Synthesis Port)
10
Notes:
a. An in-line failure of the on-board microprocessor/PSS handshake has
occurred. Refer to Test #168 for repair procedures.
b. This error type indicates that the circuit pack been removed or has been
insane for more than 11 minutes. To clear the error, reinsert or replace the
circuit pack.
c. A transient error that does not cause an alarm can occasionally occur
during a SPE, TDM BUS, or Tone Clock interchange. Test the port and
follow the instructions for conference Test (#7).
d. This error is not service-affecting and no action is required.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
NPE
Crosstalk Test,
for example, you may also clear errors generated from other tests
in the testing sequence.
For example, you may also clear errors generated from other tests in the testing
sequence.
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
Speech Synthesis PSS Handshake Test
(#168)
XXND
NPE Crosstalk Test (#6) X ND
Conference Circuit Test (#7) X ND
Speech Synthesis DTMF Receiver Test
(#163)
XND
Speech Synthesis Memory Test (#166) X X ND
Speech Synthesis DSP Tone Test (#165) X X ND
Speech Synthesis SSD Inquiry Test
(#167)
XXND
Speech Synthesis DTMF Receiver
Inquiry Test (#164)
XXND
Speech Synthesis Parameter Update
Test (#169)
XXND