DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-747HYB-LINE (Hybrid Line)
10
PASS EPF test passed. The message to turn on the power to
the station was successfully sent to the port.
1. Although this test never returns a FAIL result, after
running this test, the Error Log should be checked
for any entries with Error Type 257 to examine the
real results of this test.
2. If Error Type 257 does not appear in the Error Log
within 10 seconds after completion of this test, it is
safe to assume that the test sensed no problems
with the power to the station. To verify that the station
is powered up correctly, run a self-test on the
station, if available, and check that all the feature
buttons are operating.
3. If Error Type 257 appears in the Error Log, this
indicates some problem with the power to the
station. The system technician should check for a
short in the wiring, a damaged jack, a defective
voice terminal, or an incorrect type of terminal.
0NO
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Check to ensure that the board translations are
correct. Use the list config command, and resolve
any problems that are found.
2. If the board was found to be correctly inserted in
step 1, issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and
the port. If this is not the case, dispatch to check to
ensure that there is a valid board inserted.
Table 10-208. TEST #56 Hybrid Electronic Power Feed Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page