DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-606DTMR-PT [Dual Tone Multifrequency Port (TTR)]
10
Table 10-169. TEST #43 Tone Detector Audit/Update Test
Error
Code
Test
Result Description/ Recommendation
ABORT The system was not able to allocate all the resources
needed for this test.
1. Wait one minute and try again.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at one-minute intervals for a
maximum of five times.
2. If the test continues to abort, escalate the problem.
FAIL Hardware audit failed.
1. Run the Short Test Sequence: test port PCSSpp sh
r 1.
2. If the problem persists, the system is still operating
properly but system capacity is reduced. In order to
restore the system performance to normal, replace
the Tone Detector circuit pack containing the
defective DTMR port.
PASS The DTMR port has been successfully refreshed with its
translation.
Continued on next page