Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1120PMS-PRNT/JNL-PRNT (PMS Printer Link)
10
Link Retry Test (#215)
This test sends a message to the journal printer management software process
to make a data call to the extension where the printer device connects to. If the
journal printer link is already up, this test passes without making any data call.
1010 ABORT The link has been busied out to out-of-service.
1. Enter release journal wakeup-log|pms-log command to release the
link from busyout state.
2. Retry test journal wakeup-log|pms-log l command to execute the
test.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The link is torn down.
Table 10-331. TEST #215 Link Retry Test
Error
Code
Test
Result Description/ Recommendation
10 ABORT Internal system error
20 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
30 ABORT Internal system error
1. Refer to the ‘‘
Procedures for Restoring the PMS Printer Link’’ section for
instructions.
1010 ABORT The PMS Printer Link has been busied out to out-of-service.
1. Enter release journal wakeup-log|pms-log command to release the
link from busyout state.
2. Retry test journal wakeup-log|pms-log l command to execute the
test.
Continued on next page
Table 10-330. TEST #213 Link Tear Down Test Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page