DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-751HYB-LINE (Hybrid Line)
10
7 FAIL Conference Test failed. User may be able to use
conference circuit without difficulty in some cases. In
other extreme cases, conference calling will be totally
restricted.
The failure may be due to off-board circumstances, the
most common of which is an off-hook occurring during
the test. Also, check the error logs against the
GPTD-BD, the TONE-BD, and the TONE-PT.
1. This error can be caused by a disconnected
terminal. First, ensure that the terminal is connected
and the wiring is OK.
2. Then, issue the display port and the status station
commands to determine if the station is idle. If it is
idle, issue the test port command for this port.
3. If test continues to fail, issue the busyout port and
the release port commands, and then retest the
port.
4. It is possible that the port may still be functional from
a user’s point of view.
Table 10-209. TEST #57 Hybrid Circuit and Conference
Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page