DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-518DIOD-TRK (DIOD Trunk) [G1.2SE]
10
For example, you may also clear errors generated from other tests in the testing
sequence.
Dial Tone Test (#0)
This test attempts to seize a port and checks for the return of a dial tone.
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
NPE Crosstalk Test (#6) X ND
Dial Tone Test (#0) X ND
Loop Around and Conference Test (#33) X ND
Audit Update Test (#36) X X ND
Table 10-140. TEST #0 Dial Tone Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate system resources to run this test.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not
available. The port may be busy with a valid call. Use
the command display port PCSSpp to determine the
trunk group/member number of the port. Use the status
trunk command to determine the service state of the
port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 10, "Maintenance
Commands and Trouble-Clearing Aids" for a full
description of all possible states.) You must wait until the
port is idle before retesting.
1. If the port status is idle, then retry the command at
one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page