DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-461DID-TRK (DID Trunk)
10
1018 ABORT Test has been disabled by trunk group administration.
Verify that the "Maintenance Tests?" field on the Trunk
Group Form is set to "n." To enable the test, issue the
change trunk-group x command where "x" equals the
number of the trunk group to be tested. Then change
the entry in the "Maintenance Tests?" field on the form to
"y."
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
61446 FAIL Battery feed test failed. A loop current fault was
detected. This is most probably an incoming CO-line
problem. This failure code is only reported by the
TN2139 Italian DID circuit pack.
1. Check the incoming CO-line for loop current. If none
is detected refer the problem to the CO.
2. If the CO-line checks out OK, the failure must be on
the DID port. Replace the circuit pack.
61456 FAIL Battery feed test failed. An on-board problem was
detected. This port is out-of-service.
1. Replace circuit pack.
61472 FAIL Battery feed test failed. A problem with the incoming
CO-line was detected.
1. Check the incoming CO-line for proper operation. If
warranted, refer the problem to the CO.
2. If the CO-line checks out OK, the failure must be on
the DID port. Replace the circuit pack.
Table 10-126. TEST #35 Port Diagnostic Test — Continued
Error
Code
Test
Result Description/ Recommendation