DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1661WAE-PORT (Wideband Access Endpoint Port)
10
1000 ABORT System resources required to run this test are not
available. The port may be in use on a valid call. Use the
status access-endpoint <extension> command to
determine when the port is available for testing.
1. Retry the command at one minute intervals a
maximum of five times.
2. If the test continues to abort, and if the port is not in
use, escalate the problem.
1001 ABORT System resources required for this test are not available.
1. Retry the command at one minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions, or it may
have time slots that are out-of-service due to TDM-BUS
errors. The status health command can be used to
determine if the system is experiencing heavy traffic.
Refer to TDM-BUS Maintenance documentation to
diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors, and if it is not
handling heavy traffic, repeat the test at one minute
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-488. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page