DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-312V-PWR (12 Volt Power Supply)
10
12V-PWR (12 Volt Power Supply)
The 12 Volt Power Supply unit in the TN777B NETCON circuit pack is required for
programming flash memory devices in circuit packs such as the TN786B or
TN790 Processor circuit pack and the removable translation card. During the
erase and write operations of a flash memory or translation card, the 12 volt
power supply must be turned on under the instruction of software. For the
read-only operation, the 12 volt power supply is not required.
If the 12-volt power supply cannot be turned on, all the erase and write
operations to a flash device fail. Features such as "save translation," "save
announcements," "system upgrade," "hard patching," and "core dump" always fail
in this case.
Error Log Entries and Test to Clear Values
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. Software cannot turn on the 12 volt power supply to provide 12 volt power to the flash memory or to
the translation card.
3. Software can turn on the 12 volt power supply, and 12 volt power is available. However, the software
cannot turn the power supply off after operations are completed. The 12 volt power remains on. This
error does not affect the normal operations involved in accessing the memory or the translation
card.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run Full Name of MO
12V-PWR MINOR test card-mem sh 12 Volt Power Supply
12V-PWR WARNING test card-mem sh 12 Volt Power Supply
Table 10-1. 12 Volt Power Supply Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board
Test to Clear
Value
0
1
0 Any Any Any test card-mem
1
2
Any 12 Volt Power Supply Test
(#701)
MINOR ON test card-mem
257
3
Any 12 Volt Power Supply Test
(#701)
WARNING ON test card-mem