DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-339save announcements
8
Output
For the following output example, the command entered is "save
announcements" on a simplex SPE system.
Feature Interactions
!
WARNING:
Use of the manager I is blocked for other activities until the command
completes, which can take up to 45 minutes.
The command is denied if no announcement data module and no NETCON data
module has been administered.
The command is denied if the announcement data module port is out of service
or active (e.g. performing an announcement playback).
The command is denied if no announcements are on the board or a user is in an
integrated announcements session.
The command is denied if the board is currently being uploaded or downloaded.
A user cannot record an integrated announcement after the save
announcements command has started although 15 channels are still available for
announcement playback (one is reserved for uploading and downloading).
The command aborts if saving to the tape and no tape is in the tape drive or the
tape is write-protected. The command also abort if no NETCON data module is
available.
Processor This field displays the processor(s) that had the
announcement data written to its/their device(s). Valid
values are "SPE-A" and "SPE-B."
Command Completion Status This field specifies whether the command completed
successfully. Valid values are:
Error Code A value of "0" specifies that the save was successful. A
value of "2" specifies that the save failed.
save announcements Page 1 of 1 SPE A
SAVE ANNOUNCEMENTS
Processor Command Completion Status Error Code
SPE-A Success 0