DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1406TDM-BUS (TDM Bus)
10
Table 10-426. TEST #150 TDM Bus Clock PPM Inquiry Test
Error
Code
Test
Result Description/ Recommendation
ABORT The system could not allocate the necessary resources for the test.
1001 ABORT The system could not allocate the necessary resources for the test.
1. Wait 1 minute, and retry the test.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
255 ABORT The test was not executed because the Tone-Clock circuit pack was using
its local oscillator rather than synchronizing to an external source.
1. Verify that this Tone-Clock circuit pack is expected to be the
synchronization source. If not, correct the synchronization information
and re-execute the test.
ANY FAIL This error represents the number of PPM errors detected on the external
synchronization source since the last PPM inquiry was sent to the
Tone-Clock circuit pack. A failure of this test indicates that we are outside
of Stratum 4 or Stratum 3 timing specifications on the external timing
source. This error produces an invalid timing signal for any system that
uses this source for a synchronization reference. The error code is a
variable amount ranging from 1 to 254.
1. If there are errors against SYNC (Synchronization), refer to SYNC
(Synchronization) Maintenance documentation to change the system
synchronization reference, OR
2. If there are errors against STRAT-3 (Stratum 3 Clock), refer to the
STRAT-3 (Stratum 3 Clock) Maintenance documentation to resolve the
errors, OR
3. If there are errors against DS1-BD (DS1 Interface circuit pack), refer to
the DS1-BD (DS1 Interface Circuit Pack) Maintenance documentation
to resolve the errors, OR
Continued on next page