Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1404TDM-BUS (TDM Bus)
10
Table 10-425. TEST #149 TDM Bus Clock Slip Inquiry Test
Error
Code
Test
Result Description/ Recommendation
ABORT The system could not allocate the necessary resources for the test.
1001 ABORT The system could not allocate the necessary resources for the test.
1. Wait 1 minute, and retry the test.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
ANY FAIL This error represents the number of timing slips detected on the incoming
synchronization source since the last slip inquiry was sent to the Tone-Clock
circuit pack. The incoming synchronization source can be from one of three
sources: (1) a DS1 Interface circuit pack, (2) an EXP-INTF circuit pack if the
port network on which the test was executed does not contain the current
system synchronization reference; (3) a local oscillator on an Active
Tone-Clock circuit pack. The error code is a variable amount ranging from 1
to 255.
1. If there are errors against synchronization (SYNC), refer to the
Synchronization Maintenance documentation to change the system
synchronization reference.
2. If there are errors against DS1 Interface circuit pack (DS1-BD), refer to
the DS1 Interface circuit pack Maintenance documentation to resolve
the errors.
Continued on next page