Parameters
Help Messages
If the system technician presses HELP after entering "test trunk" the following
message will be displayed:
Enter group # or group #/member #, [’long’ or ’short’],
[’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
If the format for the trunk location is incorrect, the following error message would
be displayed:
Format invalid
If the trunk group or member range is invalid, the following message will be
displayed:
Trunk or trunk group invalid
group number The group number is an administered number associated with each
trunk group (1-99).
member number The member number is an administered number identifying a
particular trunk within a trunk group (1-99).
short This will cause the command to execute a series of nondestructive
diagnostic tests.
long This will execute a more comprehensive and longer version of the
diagnostic tests. This may involve both destructive and
nondestructive tests.
repeat number The "number" specifies how many times each test in the sequence is
to be repeated. "Number" may be any integer between 1 and 100.
clear This option causes the test sequence (short or long) to repeat until
the alarm (if one exists against the maintenance object) is cleared or
a single test in the sequence fails. If no alarms are registered against
the maintenance object then the test sequence will be exercised
only once. The long clear option forces a clear of all alarms if no
errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
schedule When the "schedule" option is specified, the command is validated
and then a scheduling form is displayed to allow the technician to
schedule execution of the command. The command is then placed
in the command queue and is executed at the specified time. The
information displayed by the command is sent to the system printer
instead of the screen. Refer to the Report Scheduler and System
Printer feature specification [1] for more details.