DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Management Terminals
Page 3-9System Login Procedure
3
10. Decide whether or not to leave the default of yes (“y”) in the Facility Test
Call Notification? field. If “y” is selected, the user receives notification at
logoff that the facility test call feature access code is administered. If you
do not want the notification to appear, set the field to “n”.
!
CAUTION:
Leaving The facility Test Call administered after logging off poses a
significant security risk.
11. Decide whether or not to leave the default of yes (“y”) in the Facility Test
Call Notification Acknowledgment Required field. If “y” is selected, the
user is required to acknowledge that they wish to logoff while Facility Test
Call is still administered. If you do not want to force the user to
acknowledge, set the field to “n”. This field appears only if the Facility Test
Call Notification field is set to 'y”
12. Decide whether or not to leave the default of yes (“y”) in the Remote
Access Notification? field. If “y” is selected, the user receives notification
at logoff that remote access is still administered. If you do not want the
notification to appear, set the field to “n”.
!
CAUTION:
To Leave Remote Access feature administered after logging off
poses a significant security risk if you are using the feature in
conjunction with the Facility Test Call feature.
13. Decide whether or not to leave the default of yes (“y”) in the Remote
Access Acknowledgment Required? field. If “y” is selected, the user is
required to acknowledge that they wish to logoff while remote access is
still administered. If you do not want to force the user to acknowledge, set
the field to “n”. This field appears only if the Facility Test Call Notification
field is set to 'y”.