DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-860MAINT (EPN Maintenance Circuit Pack)
10
Figure 10-64. EPN Expansion Links Connections
Table 10-243. TEST #229 Serial Channel Local Loop Around Test
Error
Code
Test
Result Description/Recommendation
1000 ABORT System resources required to run this test are not available.
2000 ABORT Response to the test request was not received within the allowable time
period.
2033 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2034 ABORT Background EPN Maintenance circuit pack maintenance is running the Serial
Channel Local Loop Around Test.
1. Wait 30 seconds, and retry the test a maximum of 5 times.
22901 ABORT Test disabled via software patch.
Continued on next page
ACTIVE LINK
STANDBY LINK
EXPANSION INTERFACE
CIRCUIT PACK
M
G
R
1
EPN MAINTENANCE CIRCUIT PACK
SERIAL INTERFACES
MGR 1 SERIAL
INTERFACE