DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-802ISDN-SGR (ISDN-PRI Signaling Group)
10
Error Log Entries and Test to Clear Values
Notes:
a. This switch sent a message to the far-end switch or terminal adapter, and
the far-end did not respond in the allotted time. Possible causes include
link failure and congestion or outage at the far-end. The Aux Data field
contains Layer 3 protocol information used by internal counters.
1. Run the Short or Long Test Sequence. Refer to the appropriate test description and follow the
recommended procedures.
Table 10-222. ISDN-PRI Signaling Group Error Log Entries
Error
Codes
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any test sig-group
<group>
1 (a) Any none
257 (b) Any none test sig-group
<group>
513 (c) Any none test sig-group
<group>
769 Any Primary Signaling
Link Hardware
Check (#636)
test sig-group
<group>
1025 Any Secondary
Signaling Link
Hardware Check
(#639)
test sig-group
<group>
1793 (d) Any Layer 2 Status
(Test #647)
WARNING OFF test sig-group
<group>
2049 (e) Any Layer 2 Status
(Test #647)
WARNING OFF test sig-group
<group>
2305 (f) Any Remote Layer 3
Query (Test #637)
MINOR OFF test sig-group
<group>
3585 (g) port
number
none none
3840-
3928 (h)
port
number
none