Maintenance Object Repair Procedures
Page 10-479DIG-LINE (Digital Line)
10
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may
have time slots out-of-service due to TDM-BUS errors.
Refer to TDM-BUS (TDM-Bus) Maintenance to diagnose
any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not
handling heavy traffic, repeat test at 1-minute
intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a tone receiver for the
test. The system may be oversized for the number of
Tone Detectors present or some Tone Detectors may be
out of service.
1. Look for TTR-LEV errors in the Error Log. If present
refer to TTR-LEV (TTR-Level) Maintenance
documentation.
2. Look for TONE-PT errors in the Error Log. If present,
refer to TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exist, retry the command at
1-minute intervals a maximum of 5 times.
4. If the test continues to abort, escalate the problem.
Table 10-129. TEST #1201 Digital Terminal Remote
Loop Around Test — Continued
Error
Code
Test
Result Description/ Recommendation