DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1446TIE-DS1 (DS1 Tie Trunk)
10
2000 FAIL Response to the seizure message was not received
within the allowable time period.
1. Enter the list configuration board UUCSS
command. If the circuit pack is a TN767B vintage 8
or 9, a failure of test 136 causes a subsequent failure
of test 7 due to a firmware bug. Eventually, the board
and all of its ports will be taken out of service and
extraneous on-board alarms will be generated.
Replace the circuit pack with a TN767C V3 or later.
2. Verify that the ’Trunk Type’ field on the ’Trunk
Administration’ screen matches the trunk type
administered on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware
error log. If present, refer to the DS1-BD (DS1 trunk
circuit pack) Maintenance documentation or to the
UDS1-BD (UDS1 trunk circuit pack) Maintenance
documentation.
4. Retry the test at 1 minute intervals for a maximum of
5 times.
5. If the test continues to fail, escalate the problem.
PASS The trunk can be seized for an outgoing call.
Table 10-440. TEST #136 DS1 Tie Trunk Seizure Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page