DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1551UDS1-BD (UDS1 Interface Circuit Pack)
10
1004 ABORT Received an incoming call on a port of the UDS1 circuit
pack during the test.
1. Enter the busyout board PCSS command to put all
trunks or ports of the UDS1 Interface circuit pack to
out-of-service state.
2. Retry the reset board command at 1-minute
intervals a maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1015 ABORT Ports on the UDS1 Interface circuit pack have not been
busied out to out-of-service.
1. Enter the busyout board PCSS command to put all
trunks or ports of the UDS1 Interface circuit pack
into the out-of-service state.
2. Retry the reset board command.
3. If the test continues to abort, escalate the problem.
1039 ABORT The UDS1 Interface circuit pack is providing timing for
the system. Executing this test could cause major
system disruption. If the UDS1 Interface circuit pack
needs to be tested, set the synchronization reference to
another DS1 Interface circuit pack or to the Tone-Clock
circuit pack via the following command sequence:
1. Issue the disable synchronization-switch
command.
2. Next, issue the set synchronization PCSS
command.
3. Lastly, issue the enable synchronization-switch
command. Then rerun the test. If the test aborts
again, a different ABORT error code will be
generated. Follow the recommended maintenance
procedures for that error code.
2000 ABORT Response to the test request was not received within the
allowable time period. If Error Type 1538 is present in
the Error Log, follow the maintenance strategy
recommended for this error type.
Table 10-459. TEST #135 Internal Loop Around Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page