DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-967M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386]
10
Table 10-278. TEST #9 NPE Cross Talk Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not
available. The port may be in use on a valid ISDN-PRI
test call. Use the list isdn-testcall command to
determine if the port is in use (if the port is listed in the
M/T Port column). If it is in use, either wait for the test call
to complete (as indicated in the Start Time and Duration
fields in the above display), or abort the test call with the
clear isdn-testcall tg/mem command, where tg/mem is
determined from the B-channel field of the above
display.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort and the port is not in
use, escalate the problem.
1001 ABORT System resources required to run this test are not
available.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may
have time slots out of service due to TDM-BUS errors.
Refer to TDM-BUS Maintenance documentation to
diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not
handling heavy traffic, repeat test at one-minute
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page