Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-405DATA-CHL (Network Control Data Channel)
10
2011
2012
2013
2016
2017
2020
2022
2051
ABORT Refer to STBY-SPE (Standby SPE) for a description of these error codes.
14
16
40
2000
2003
2004
FAIL In the case of Error Code 40, the Crosstalk Test failed because the data
received over the connection did not match the data sent over the connection
(data was corrupted). In the case of Error Code 2000, 2003, and 2004, the
crosstalk test failed because the data looped over the connection was not
received (data was lost).
1. Determine which of the DATA-CHLs are in use for some other function
(that is, CDR Link, System Printer Link, Journal Printer Link, PMS Link, or
secondary administration terminal connection) as described previously in
the "Status of Network Control Data Channels" section.
2. Note the test result for Test #111 in the Short Test Sequence for the target
DATA-CHL and refer to Steps 3 and/or 4 to determine the appropriate
actions to take based on those results.
3. If the result of Test #111 is PASS, then the most likely problem is that the
TDM Bus or Tone-Clock circuit pack is defective.
a. Check for the existence of TDM Bus (TDM-BUS) and/or Tone-Clock
circuit pack (TONE-BD, TONE-PT, and TDM-CLK) errors and alarms.
If they exist:
1. Refer to the corresponding Maintenance documentation to clear
the errors and alarms.
2. Repeat the test.
b. If TDM Bus (TDM-BUS) and/or Tone-Clock circuit pack (TONE-BD,
TONE-PT, and TDM-CLK) errors and alarms do not exist, investigate
the possibility that the target DATA-CHL, the DATA-CON, or the
Network Control circuit pack is defective as described in Step 4.
Table 10-111. TEST #110 Data Channel Crosstalk Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page