DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1022PDMODULE, TDMODULE (Data Module)
10
3004 ABORT 1. This error could be caused by the switch setting of
the PDM. Verify that the switch on the PDM is set to
the "remote loop" position. When the remote loop
around test is completed, return the switch to the "off"
position.
2. This error could be caused by the Network Control
Data Channel. Look for DATA-CHL errors in the
Hardware Error Log.
3. This error could also result if no data equipment is
connected to the data module. Verify that (a) the
data equipment is properly connected to the data
module, (b) that power is available to the data
equipment, and that (c) the data equipment is
powered on.
4. This error could also occur if the baud rate of the
data module is set to 19.2 Kbps since the Network
Control circuit pack used by this test does not
support baud rates greater than 9600 bps. Verify that
the baud rate of the data module is set to 9600 bps
or less.
1040 FAIL Data received from remote loop back does not match
data sent.
1. Check for faulty wiring.
2. Replace the data module and repeat the test.
3. If the test fails, replace the Digital Line circuit pack
associated with the data module and repeat the test.
4. If the test continues to fail, escalate the problem.
1070 FAIL Internal software response.
1. Wait one minute and attempt the test again.
2. If the same error persists after five attempts in
one-minute intervals, escalate the problem.
Table 10-292. TEST #175 Data Module Internal
Loop Around Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page