DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-94ANN-BD (Announcement Circuit Pack)
10
against the ANN-BD without alarming the TONE-BD. If this error occurs
again, replacing the Tone-Clock circuit pack may clear up this error. See
the FAIL case in the Clock Match Inquiry Test (#212).
n. Error Type 3840
This error is not service-affecting and no action is
required.
o. Error type 3999
Indicates that the circuit pack sent a large number of
control channel messages to the switch within a short period of time. If
error type 1538 is also present, then the circuit pack was taken
out-of-service due to hyperactivity. If error type 1538 is not present, then
the circuit pack has not been taken out-of-service, but it has generated
50% of the messages necessary to be considered hyperactive. This may
be completely normal during heavy traffic periods. However, if this error
type is logged when the circuit pack is being lightly used, it may indicate a
problem with the circuit pack or the equipment attached to it.
p. Error Type 2
Check the Class of Restriction (COR) administered for the
Data Line extension assigned to the TN750 for uploading and
downloading announcements. The extension can be found by using list
data-module.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in Table 10-33 when inspecting
errors in the system. By clearing error codes associated with the
Control Channel
Loop Around Test
, for example, you may also clear errors generated from other
tests in the testing sequence.
Table 10-33. System Technician-Demanded Tests: ANN-BD
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset
Board
Sequence D/ND
1
Control Channel Loop Around Test (#52) (a) X ND
Angel-Speech Processor (SP) Handshake Test
(#208)
XND
Clock Match Inquiry (#212) X X ND
Super Frame Match Inquiry (#211) X X ND
140AY Loop Around Test (#210) X X ND
Announcement Checksum Test (#209) X X ND
Network Processor Element (NPE) Audit Test
(#50) (a)
XND
Continued on next page