Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-264monitor trunk
8
Defaults
The member number defaults to 1 if a group is specified without a member.
Parameters
Help Messages
If the system technician presses HELP after entering "monitor trunk", the following
message is displayed:
Enter assigned trunk group(1-99) or [group/member(1-99)]
Error Messages
If the format of the trunk identifier is incorrect, the following error message is
displayed:
Format invalid
If the trunk identifier is not in the valid range, the following error message is
displayed:
Trunk or trunk group invalid
If the trunk group member is not administered, the following message is
displayed:
Group member not assigned
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message is displayed:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message is displayed:
All maintenance resources busy; try again later
group The group number is an administered number associated with each trunk
group. The valid range is 1 - 99. If a group number is entered without a
member number, member number defaults to 1.
member The member number is an administered number identifying a particular
member within a trunk group. The valid range is 1 - 99. If a member
number is entered, status for that member is displayed.