DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Routine Maintenance Procedures
Page 5-23Software Upgrade
5
press Enter. Where P is the port network number (1 for PPN, and 2-4 for
EPN), C is the carrier designation (A, B, C, or D), and SS is the number of
the slot in which the circuit pack resides (01 to 21).
NOTE:
If multiple TN750/B circuit packs are present, you
must
specify the
slot location for the save announcements command. If there is only
one announcement circuit pack, the system defaults to the proper
location.
NOTE:
The TN750C Announcement circuit pack has on-board non-volatile
storage and does not need to be saved to the translation card.
Shut Down DEFINITY LAN Gateway System
If a DEFINITY LAN Gateway system resides in the control cabinet to be
upgraded, prepare to shut down the DEFINITY LAN Gateway assembly and
allow the disk to completely spin down.
!
CAUTION:
Save the system parameters if you plan to reuse the current system.
!
CAUTION:
Neglecting to shut down a DEFINITY LAN Gateway assembly before
powering down the system cabinet where it resides can damage the LAN
Gateway disk.
1. Log onto the DEFINITY LAN Gateway.
See the DEFINITY Communications
System Generic 3 Installation, Administration and Maintenance of
CallVisor ASAI over the DEFINITY LAN Gateway
, 555-230-223, for the
procedure to log on.
2. When the main menu appears, select
Maintenance
.
3. Select
Reset System
from the
Maintenance
menu.
4. Select
Shutdown
from the
Reset System
menu.
5. Unseat the LAN Gateway assembly from its backplane connectors.
Shut Down DEFINITY AUDIX System
1. If a DEFINITY AUDIX System resides in the control cabinet to be
upgraded, shut down the AUDIX assembly and allow the disk to
completely spin down.