DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-976M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386]
10
Hook State Inquiry (#566)
This test ensures that the Maintenance/Test Digital Port maintenance software
and call processing agree on the on-/off-hook status of the Maintenance/Test
Digital Port.
50 FAIL The switch was unable to communicate with the port
circuitry used for digital trunk testing.
100 FAIL Data was not sent from Port 2 to Port 3 successfully in
asynchronous mode.
101 FAIL Data was not sent from Port 3 to Port 2 successfully in
asynchronous mode.
102 FAIL Data was not sent from Port 2 to Port 3 successfully in
synchronous mode.
103 FAIL Data was not sent from Port 3 to Port 2 successfully in
synchronous mode.
1. Reset the circuit pack via the busyout board PCSS,
reset board PCSS, release board PCSS command
sequence.
2. Test the port again via the test port PCSS02 l
command.
3. If the test fails again, replace the circuit pack.
PASS The Maintenance/Test Digital Port digital trunk testing
capability is operating correctly.
Table 10-281. TEST #161 Loop Around Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page