Maintenance Object Repair Procedures
Page 10-42ADX16A-PT (AUDIX Analog Line/Control Link)
10
Note:
a. Retry the command at 1-minute intervals a maximum of 5 times.
Loop Around Test (#161)
This test is designed to check the on-board transmission capabilities of the NPE
on the analog port.
Any FAIL The NPE of the tested port did not conference the tones correctly. This causes
noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port can correctly conference multiple connections. User-reported
troubles on this port should be investigated by using other port tests and by
examining station, trunk, or external wiring.
Table 10-18. TEST #161 Loop Around Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources for this test. Try (a).
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call. Use the display port PCSSpp command to determine
the station extension. Use the status station command to determine the
service state of the port. If the port is in use, wait until it is idle before testing.
1. If the port status is idle, try (a).
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to “TDM-BUS” to diagnose TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, try (a).
Continued on next page
Table 10-17. TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page