DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-10busyout data-module
8
Output
For the following output example, assume that the command that was entered is
"busyout cdr-link primary."
Feature Interactions
None.
busyout data-module
This command will busyout a system technician specified data module or data
channel.
Synopsis
busyout data-module extension
Port The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being busied out. With this maintenance object a
port address of 1 represents the primary link, while a 2 port
address is associated with the secondary link.
Maintenance Name The type of maintenance object that is being busied out.
Alt. Name The alternate means of identifying the maintenance object. This
field contains the extension when the object is a station, and it
contains xxx/yyy when the object is a trunk, where xxx is the trunk
group number and yyy is the member number. It contains P/xxx
when the object is a private CO line, where xxx is the private CO
line group number.
Result An indicator as to whether the object was successfully busied
out.
Error Code A numerical description of why the command failed.
busyout cdr-link primary SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
1 CDR-LNK PASS
Command successfully completed