DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1267STBY-SPE (Standby SPE)
10
r. Error Type 804 is logged when the upgrade software command failed
due to a loss of communication with the Standby SPE during the reboot
immediately following a successful software upgrade. This implies that the
communication path between the Active SPE and the Standby SPE may
not be functional.
Issue the test duplication-interface a and the test duplication-interface
b commands. If the tests pass, re-execute the upgrade software
command.
s. Error Type 805 is logged when the upgrade software command failed
due to the failure to insert the software card-mem in the Active SPE in time.
The software card-mem should be inserted into the Active SPE at the
appropriate time so as to allow the upgrade software command to be
re-executed.
t. Error Type 806 is logged when the upgrade software command failed
due to a bad flash checksum on the new Standby SPE after an upgrade of
the old Standby SPE and SPE-Interchange. This implies that the on-board
flash memory may not be functional. The behavior of the Standby SPE may
unpredictable.
The upgrade software command should be re-executed. If the command
fails again, the Standby SPE Processor circuit pack should be replaced.
u. Error Type 807 is logged when the upgrade software command failed
due to the failure to insert the translation card-mem into the new Standby
SPE after an upgrade of the old standby SPE and SPE-Interchange.
The translation card-mem should be inserted into the Standby SPE.
v. Error Type 808 is logged when the upgrade software command failed
due to the loss of communication with the new Standby SPE during an
upgrade following the upgrade of the old standby SPE and
SPE-Interchange. This implies that the programming of the Standby SPE
never completed.
Use the "Special Upgrade Procedure" to re-execute an upgrade on the
Standby SPE only. If the upgrade fails again, the Standby SPE Processor
circuit pack should be replaced.
w. Error Type 809 is logged when the upgrade software command failed
due to the failure to perform an SPE-Interchange immediately after the
successful upgrade of the Standby SPE. This implies possible problems
with the Dupint circuit packs.
Issue the test duplication-interface a and test duplication-interface b
commands. If the tests pass, re-execute the upgrade software
command.
x. Error Type 810 is logged when the upgrade software command failed
due to a bad checksum on the software card-mem during the upgrade of
the new Standby SPE following the successful upgrade of the old Standby
SPE and of SPE-Interchange.