DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-627test network-control
8
use the "refresh spe-standby" command.
If the standby SPE is not refreshed and the active SPE is hard selected via the
SPE select switches when this command is executed, then the following
message is displayed:
Active SPE locked via select switches;
Standby SPE memory not refreshed
If the standby SPE is busy with another task, then the following message is
displayed:
Standby SPE busy with another task;
for information use "status system 1"
If the standby SPE is not available when this command is executed, then the
following message is displayed:
Standby SPE not available;
for information use "status system 1"
Output
The responses will be displayed on a test-by-test basis with one line of data
displayed for each test result.
Port The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being tested. This object is always associated with
cabinet 1. For maintenance objects: DATA-BD, SW-CTL,
12V-PWR, CARD-MEM, the slot and circuit fields of port address
are blank. The administered data channel maintenance object,
DATA-CHL, uses the "XX" as the slot address and has a circuit
number between 01 and 04. The carrier field has a value "A" for
the control carrier A in a simplex system, and "A" or "B" for control
carriers A and B in a duplex system.
Maintenance Name The type of maintenance object that is being tested. The
maintenance objects are: DATA-BD for Network Control board,
SW-CTL for Switch Control Arch-angel, DATA-CHL for
administered data channel, 12V-PWR for 12 volt power supply
unit on Network Control board, CARD-MEM for flash memory card
on Network Control board. 12V-PWR and CARD-MEM are shown
only when the Network Control board is TN777B.
Alt. Name This field contains the extension number of the DATA-CHL if
administered. For other maintenance objects, this field is not
applicable and left empty.