Maintenance Object Repair Procedures
Page 10-1559UDS1-BD (UDS1 Interface Circuit Pack)
10
1303 FAIL The DS1 circuit pack Suffix is incorrect for CSU Module
administration. The
Near-End CSU Type
field on the
add
ds1
form has been administered as
integrated
but the
DS1 circuit pack is not a TN464F or later suffix UDS1
board.
1. If the CSU Module is to be used, and the
Near-End
CSU
type field is set to
intergrated
to allow for CSU
Module administration, remove the circuit pack and
replace with a TN464F or later suffix board.
Otherwise, use the
change ds1
command to
change the
Near-End CSU Type
field to
other
.
1310 FAIL The DS1 Board Loopback (BLB) demand test (#1209)
failed.
1. Repeat the test using the
test ds1-loop PCSS
ds1/csu-loopback-tests
command.
2. If the BLB test continues to fail, then replace the
TN464F circuit pack. 3) Run this test again.