DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-258monitor system
8
Max_callrate This field represents the maximum call rate which has been hit during
the time since the last hour has passed. If, for example, at 20 minutes
past 12:00 this command is executed, this field will represent the
maximum call rate obtained during the past 20 minutes. This field
represents real-time status data.
Next_hour This field will contain a value of 0 or 1 depending upon if the
measurements being taken are for this hour or the next. It is related to
the previous field in that the maximum call rate is reflected for this hour.
When this flag is set, then statistics begin to accumulate for the next
hour and shortly thereafter, the maximum call rate will become zero and
accumulations will begin anew.
tot_ts_req This field holds the total time slots in use during the time period elapsed
since the top of the last hour. Data is internally collected every 100
seconds. When the timer fires and the data collection occurs, a check
is made as to how many time slots are currently in use. That’s where the
total comes from. There are three numbers displayed for this field on
the form; one for each of the pnns requested. This field represents
real-time status data.
ts_denied This field holds the total time slots requests that were denied during the
time period elapsed since the top of the last hour. Data is internally
collected every 100 seconds. There are three numbers displayed for
this field on the form; one for each of the pnns requested. This field
represents real-time status data.
tot_fts_req This field represents the total fiber time slots that have been requested.
This field is incremented each time a fiber time slots that have been
allocated since the last top of the hour measurements polling. There
are three values shown on the form; one for each of the requested
pnns. This field represents real-time status data.
ts_count This field indicates how many time slots are in use during the last 100
second poling period. An internal timer causing polling to occur every
100 seconds. The value in this field represents the requests for time
slots during that 100 second interim. There are three numbers
displayed for this field on the form; one for each of the pnns requested.
This field represents real-time status data.
ts_total This field gets it’s value from the time slots count field discussed above
every 100 seconds. It represents the total number of time slots
requested since the top of the last hour and is real-time status data.
fts_count This field indicates how many fiber time slots are in use during the last
100 second poling period. An internal timer causing polling to occur
every 100 seconds. The value in this field represents the requests for
fiber time slots during that 100 second interim. There are three
numbers displayed for this field on the form; one for each of the pnns
requested. This field represents real-time status data.