DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-560test cdr-link
8
For information on what a CDR link is and does, see the second paragraph in the
"Description" section of the "status cdr-link" manual pages.
Defaults
The default for the command is short with the repeat of 1.
Parameters
Help Messages
If the system technician presses HELP after entering "test cdr-link" the following
message will be displayed:
Enter ’primary’ or ’secondary’
If the system technician presses HELP after entering "test cdr-link primary" or "test
cdr-link secondary" the following message will be displayed:
Enter [’long’ or ’short’],
[’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
If the link is not administered, the following error message will be displayed:
link-id A "Link-id" is either "primary" or "secondary".
short This will cause the command to execute a series of nondestructive
diagnostic tests.
long This will execute a more comprehensive and longer version of the
diagnostic tests. This may involve both destructive and nondestructive
tests.
repeat number The "number" specifies how many times each test in the sequence is to
be repeated. "Number" may be any integer between 1 and 100.
clear This option causes the test sequence (short or long) to repeat until the
alarm (if one exists against the maintenance object) is cleared or a
single test in the sequence fails. If no alarms are registered against the
maintenance object then the test sequence will be exercised only
once. The long clear option forces a clear of all alarms if no errors are
encountered during testing. The short clear option only clears alarms
pertinent to tests in the short sequence.
schedule When the "schedule" option is specified, the command is validated
and then a scheduling form is displayed to allow the technician to
schedule execution of the command. The command is then placed in
the command queue and is executed at the specified time. The
information displayed by the command is sent to the system printer
instead of the screen. Refer to the Report Scheduler and System
Printer feature specification [1] for more details.