DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-724FL-DATA (Flash Data Consistency)
10
12 FAIL Load vintages and announcements are different in both SPEs. The
Active SPE has the most current announcements.
1. Follow the procedures for Error Codes 4 and 8.
13 FAIL The translations, announcements, and load vintages are different in
both SPEs. The Active SPE has the most current translations and
announcements.
1. Follow the procedures for Error Codes 4 and 10.
14 FAIL The translations, announcements, and load vintages are different in
both SPEs. The Standby SPE has the most current translations, and
the Active SPE has the most current announcements.
1. Follow the procedures for Error Code 4. Be sure to issue the save
announcements command.
16 FAIL Announcements are different in both SPEs. The Standby SPE has the
most current announcements.
1. Follow the procedures for Error Code 8.
17 FAIL The translations and announcements are different in both SPEs. The
Active SPE has the most current translations and the Standby SPE
has the most current announcements.
18 FAIL The translations and announcements are different in both SPEs. The
standby SPE is the most current.
1. Follow the procedures for Error Code 9.
20 FAIL The load vintages and announcements are different in both SPEs.
The Standby SPE has the most current announcements.
21 FAIL The translations, announcements, and load vintages are different in
both SPEs. The Active SPE has the most current translations and the
Standby SPE has the most current announcements.
22 FAIL The translations, announcements, and load vintages are different in
both SPEs. The Standby SPE has the most current translations and
announcements.
1. Follow the procedures for Error Code 4. Be sure to issue the save
announcements command.
Table 10-205. TEST #421 Flash Data Consistency Check Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page