Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-254monitor system
8
Parameters
Help Messages
If the system technician presses HELP after entering "monitor system", the
following object command word choices will be displayed:
conn view1 view2
scr
If the system technician presses HELP after entering "monitor system conn" the
following message will be displayed:
Enter 3 port network numbers(xx-xx) [’pnn’ x x x]
Error Messages
If the pnn number entered is non numeric, not administered, or invalid in any
other way, one of following messages will be displayed:
Object command word omitted; please press HELP
"xx" is an invalid identifier; press RETURN to execute modified command
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
Command resources busy; Press CANCEL to clear, and then resubmit
view1 This specifies a form that will include the attendant status, the
maintenance status, the last hour’s measurement of trunk groups, hunt
groups, and the attendant group, and finally, the time of day.
view2 This specifies a form that will display a subset of the view1 form entries.
This form will include all of the view1 form except the last hour’s hunt
group measurements.
conn This option will bring up the connection monitor output for key
information.
entering no
options
Omitting the "pnn # # #" argument on the command line will cause the
default configuration of Pnn’s 1, 2 and 3 to be displayed.
pnn # # # Entering "pnn # # #", where "#" is replaced by a pnn number from 1 to 3,
will cause data for the specified pnns to be displayed.
entering no options Omitting the "pnn # # #" argument on the command line will cause
the default configuration of Pnn’s 1, 2 and 3 to be displayed.
pnn # # # Entering "pnn # # #", where "#" is replaced by a pnn number from
1 to 3, will cause data for the specified pnns to be displayed.