DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-549test analog-testcall
8
Output
The responses will be displayed on a test-by-test basis with one line of data
displayed for each test result.
For the following output example, assume that the command that was entered
was "test analog-testcall trunk 78".
Feature Interactions
Additional data is available after running a test. See the list measurements
test-calls command for details on how to access the additional data.
If the trunk is in use by call processing the test will abort.
If the trunk is in use by maintenance, the test will queue and will run when the
current maintenance activity finishes.
Port The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being tested.
Maintenance Name The type of maintenance object that is being tested.
Alt. Name The alternate means of identifying the maintenance object. This
field contains xxx/yyy when the object is a trunk, where xxx is the
trunk group number and yyy is the member number.
Test No. The actual test that is being executed.
Result The result of the individual test -"PASS," "ABORT," "FAIL," "NO
BOARD," "DISABLED," "EXTRA BD."
Error Code A system-generated number that tells why the test failed or
aborted. A detailed list of the codes according to "Test No." is
provided for each MO (for example, CO_TRK Transmission Tests
(#844-849).
test analog-testcall trunk 78
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1505 CO-TRK 78/1 845 PASS
01C1507 CO-TRK 78/2 845 PASS
Command Successfully Completed