Table 10-452. TEST #90 Tone Generator Crosstalk Test
Error
Code
Test
Result Description/ Recommendation
None ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, follow normal
escalation procedures.
1001 ABORT The system was not able to put the tone generation
facility in the appropriate mode to test it.
1002 ABORT The system could not allocate time slots for the test
connection. This can happen when the system is heavily
loaded. If the system is not heavily loaded, then test the
TDM-BUS via the test tdm port-network PN#
command. Refer to TDM-BUS section for details.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, follow normal
escalation procedures.