DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1045PI-BD (Processor Interface Circuit Pack)
10
short time. If the firmware checksum fails during scheduled maintenance, then
the circuit pack can be downloaded again at this time instead of during the SPE
interchange. The Processor Interface firmware can be unconditionally
downloaded to the Standby SPE circuit pack via the reset interface PCS
command, where PCS is the carrier/slot of a Standby PI. The command executes
the Standby Processor Interface Board Test (#423), but with a download option.
The Active Processor Interface circuit pack is tested in the PI-SCI (System
Communication Interface) Maintenance documentation. Refer to that section for
details. The test command is test interface PCS where PCS is the port network
number, carrier, and slot of one of the Standby Processor Interface circuit packs.
If the Standby Processor Interface circuit pack is tested, the test sequence for
the Standby Processor Interface is followed. If the Active Processor Interface
circuit pack’s PCS is given, then tests in the Active Processor Interface test
sequence are run. On the Active PI, if there are no enabled Processor Interface
links on the Communication-Interface Links Form, only the XXX-BD (Common
Port Circuit Pack) tests execute.
Error Log Entries and Test to Clear Values
Table 10-302 indicates entries that may be found in the Error Log for Processor
Interface circuit packs. Since the Processor Interface circuit pack has common
port board functionalities, then cross reference XXX-BD (common port board)
maintenance information for more information. Test #423 is the only test
described in this section. XXX-BD maintenance describes the other tests
mentioned in the following table.
Table 10-302. PI-BD Error Log Entries
Error
Code
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test interface PCS sh r 1
1 (a) 0 Circuit pack removed
or SAKI Test (#53)
MINOR ON
23 (b) 0 None WARNI
NG
OFF
54 (c) 0 None MAJOR ON test interface PCS l
124 (d) Any None MAJOR ON test interface PCS l
125 (e) None MINOR ON
257 65535 Control Channel Test
(#52)
MINOR ON test interface PCS
257 (f) Any None
513 (g) Any None
Continued on next page