DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-711EXT-DEV ADMIN? N (External Device Alarm)
10
b. Refer to EMG-XFER (Emergency Transfer) section for a description of this
test.
c. Refer to RING-GEN (Analog Ring Generator) section for a description of
this test.
External Device Alarm Test (#120)
The External Device Alarm Test requests the state of the External Device Alarm
from the Maintenance circuit pack and reports the results. The test has no effect
on the external device itself.
Table 10-201. TEST #120 External Device Alarm Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not
available.
1. Retry the command at 1 minute intervals a maximum
of 5 time.
2. If the test continues to abort, escalate the problem.
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at 1 minute intervals a maximum
of 5 time.
2. If the test continues to ABORT with error code 2000,
check for system powering problems with the A
carrier (PPN or EPN). Look for and resolve all
AC-POWER and CARR-POW alarms in a multicarrier
cabinet or DC-POWER alarms in a single carrier
cabinet. Then, repeat the test.
3. If the test continues to ABORT with a 2000 error
code, check for and resolve all SYSAM errors in a
PPN or MAINT (EPN Maintenance circuit pack)
errors in an EPN. Then, repeat the test.
4. If the test continues to ABORT with a 2000 error
code, then escalate the problem.
2029
2319
2320
2500
ABORT Internal System Error
1. Retry the command at 1 minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
Continued on next page