DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-195list measurements
8
Cannot get time from system clock
Output
The following field descriptions pertain to the summary reports accessed by the
"list measurements ds1 summary" command.
Counted
Since:
The start time and date when the associated measurement counters
were cleared or the DS1 circuit pack was administered.
Number of
Seconds
Elapsed Into
Current
15-min
Interval:
The number of seconds from the beginning of the current 15-minute
interval. This field has a value from 0 to 900.
Total of Valid
15-min
Intervals in
Past 24-hr
Period:
The total number of 15-minute intervals in the past 24-hour period that
contain valid data. This field has a value from 0 to 96.
Category The four categories correspond to four measurement error counters.
The four categories are "Errored Seconds," "Bursty Err Secs," "Severely
Err Secs," and "Failed Seconds". The meanings of each category
follow:
The value of the errored seconds counter for the specified
15-minute interval. This field has a value from 0 to 900 or N/A if the
data for the 15-minute interval is invalid.
The value of the bursty errored seconds counter for the specified
15-minute interval. This field has a value from 0 to 900 or N/A if the
data for the 15-minute interval is invalid.
The value of the severely errored seconds counter for the specified
15-minute interval. This field has a value from 0 to 900 or N/A if the
data for the 15-minute interval is invalid.
The value of the failed seconds counter for the specified 15-minute
interval. This field has a value from 0 to 900 or N/A if the data for
the 15-minute interval is invalid.