Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-582test environment
8
Error Messages
If the entered cabinet location is greater than two characters or otherwise invalid,
the following error message is displayed:
Identifier invalid
If the indicated EPN is not available, the following message is displayed:
EPN is not available
If the command entered is in conflict with another currently executing command,
then a message is displayed showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
Output
The responses will be displayed on a test-by-test basis with one line of data
displayed for each test result.
For the following output example, assume that the command that was entered
was "test environment 1" to test a MCCPPN cabinet.
Port The port address (cabinet-carrier) of the maintenance object that
is being tested. For all but the CARR-POW maintenance object,
only the cabinet value is displayed. For the CARR-POW
maintenance object, both the cabinet and carrier values are
displayed.
Maintenance Name The type of maintenance object that is being tested.
Alt. Name Not applicable.
Test No. The actual test that is being executed.
Result The result of the individual test -"PASS," "ABORT," "FAIL,"
"DISABLED.”
Error Code A system-generated number that tells why the test failed or
aborted. A detailed list of the codes according to "Test No." is
provided for each MO.