DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-642test port
8
If the EPN on which the port resides is not accessible, the following message will
be displayed:
EPN is not available
If the board on which the port resides is not configured in the system, the
following message will be displayed:
Port not assigned
If there are no tests found for this maintenance object, the following message will
be displayed:
No tests for this MO
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message will be displayed:
All maintenance resources busy; try again later
Output
The responses will be displayed on a test-by-test basis with one line of data
displayed for each test result.
Port The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being tested.
Maintenance Name The type of maintenance object that is being tested.
Alt. Name The alternate means of identifying the maintenance object. This
field contains the extension when the object is a station, and it
contains xxx/yyy when the object is a trunk, where xxx is the trunk
group number and yyy is the member number. It contains P/xxx
when the object is a private CO line, where xxx is the private CO
line group number.