9009 Operation timed out. 1. Follow the instructions provided in the
‘‘
Tape Maintenance and Repair
Procedures’’ section.
2. If the problem still exists, escalate the
problem.
9010 Hardware not responding.
9011 Internal system error. Escalate the problem.
9012 Tape already in use. 1. If the Tape Unit is in use (that is, the
yellow LED on the tape drive is on and
there is tape cartridge motion), wait
until the first request is complete. If
there does not appear to be tape
motion and/or the yellow LED on the
tape drive is not on, go to next step.
2. Retry the test tape command at
one-minute intervals a maximum of five
times. If the command continues to
abort, escalate the problem.
9013 Tape drive self-test failed. 1. Follow the instructions provided in the
‘‘
Tape Maintenance and Repair
Procedures’’ section.
2. If the problem still exists, escalate the
problem.
9015 Test detected hardware
failure.
9017 Could NOT reset the tape
drive.
9020
!
WARNING:
The tape cartridge is
starting to wear, but it
is still functional.
Table 10-415. Table A: Tape Unit Aux Data Table — Continued
Aux Data/
Error Codes Explanation Strategy
Continued on next page