DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-923MODEM-PT (Modem Pool Port)
10
Figure 10-68. Modem Pool Conversion Resource Loop Around Test Set-up
Test data patterns are transmitted from the Network Control Channels 1 or 3 over
network time slot A through the digital port, looped around through the analog
port via time slot C back to the Network Control Channel circuit via time slot B
where the patterns are checked for accuracy. Finally, the test forces a
disconnect by breaking the connection between the Data Channel and Modem
Pool Port (time slot A) and verifying that the Data Channel and Modem Pool Port
go on-hook within the proper time.
This test attempts to allocate a Network Control Channel, Modem Pool Port, and
other internal resources. If any of these allocation attempts fail, the test cannot be
completed and a specific abort error is reported.
TS-A
Network
Control
(TN727)
Data
Channel
TN758 Pooled Modem Circuit Pack
Modem Pool Conversion Resource
(One of Two)
TS = Time Slot
TS-C
Analog
Portion
Digital
Portion
TS-B