DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1159PR-MAINT (Maintenance Processor)
10
MTP Analog Loop Around Test (#103)
This test is a nondestructive test. The test does an on-board loop around by
using the MTPINADS channel. Test data is sent through the on-board modem out
toward the INADS trunk. The data is looped around before the actual trunk, and it
comes back into the on-board modem. The data is then verified for integrity.
NOTE:
The test does not send any data onto the INADS trunk. However, in order to
pass, the test does require the trunk to be present.
10206 ABORT System could not determine if the testing of the INADS port is administered.
1. Enter the change system-parameters maintenance command. Verify
that the "Test Remote Access Port?" field is set to "y."
2. Retry the command at 1-minute intervals a maximum of 5 times.
10208 ABORT The remote access port is busy. INADS is probably dialed into the switch.
1. If INADS is dialed in, the INADS trunk is working. There is no need to run
the test.
Table 10-347. TEST #103 MTP Analog Loop Around Test
Error
Code
Test
Result Description/ Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT (Refer to STBY-SPE Maintenance documentation for a description of these
error codes.)
Continued on next page
Table 10-346. TEST #102 MTP Outpulse Relay Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page