DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-511DIOD-DS1 (DS1 DIOD Trunk)
10
FAIL The trunk cannot be seized for an outgoing call.
1. Verify that the Trunk Type field on the trunk
administration screen form matches the trunk type
administered on far end switch.
2. Look for UDS1-BD errors in Hardware Error Log. If
present, refer to the UDS1-BD (DS1/UDS1 Trunk
Circuit Pack) Maintenance documentation.
3. Retry the test at 1-minute intervals for a maximum of
5 times.
4. If the test continues to fail, escalate the problem.
PASS The trunk can be seized for an outgoing call.
Table 10-138. TEST #314 DS1 CO Dial Tone Seizure Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page